When acting in the capacity of
owner/builder, the owner is, in essence, a contractor. Therefore, the same
requirements are necessary for construction permits:
 |
A completed permit application. |
|
|
|
A complete legal description of
the property. |
|
|
|
Proof of property ownership.
This
can be a copy of a "recorded deed", current tax statement
from the County Tax Assessor, or "Homestead Exemption Card". |
|
|
|
If the construction value exceeds
$2,500.00, a copy of the Notice of Commencement and a notarized
affidavit, stating that the Notice has been filed for recording, is
required to be submitted prior to obtaining the first inspection. A
copy of the recorded Notice of Commencement is required prior
to further inspections. |
|
|
|
Energy calculations are required
for new construction and additions only. Forms are available from the Building Department
or can be prepared by an air conditioning company or an insulation
company. |
|
|
|
When applicable, attach a copy of
any variance that will apply to this application/construction, or a
copy of Architectural Review Board (A.R.B.) approval. |
|
|
|
Two (2) copies of a survey
are required, showing where the addition if located on the property,
draw to the same scale as the survey (reduced copies of surveys
will not be accepted, all surveys must be a full copy - to scale). |
|
|
|
Garage Doors shall have a
Certified Drawing for the Garage Door, signed, dated, and sealed by a
Professional Engineer, registered in the State of Florida, or Florida
Product Approval Information. |
|
|
|
Two sets of building plans,
drawn to scale, on a minimum 8 ½ x 11 sheet of paper. Plans are
required to be sealed by an engineer or architect, stating
compliance with Section 1606 of the 2004 Florida Building Code for 125 mph land side,
130 mph beach side. |
The following is required to be shown on
the plans:
|
Floor plan showing use of space,
existing & proposed |
|
|
|
Calculated total living area, garage
area and patio areas where applicable |
|
|
|
Wall sections including framing
materials and spacing |
|
|
|
Roof framing layout and overhang
including material, spacing, and uplift sealed by the truss company or engineer of record. |
|
|
|
Electrical layout showing any new
outlets and fixture locations |
|
|
|
Smoke detector locations -
required inside and outside of each bedroom. ARC fault protection
required in each bedroom. |
|
|
|
Location of GFI outlets as required
by the National Electrical Code Section 210-8(a) |
|
|
|
New plumbing fixtures and connections to
existing system |
|
|
|
Any fixtures that will be gas |
|
|
|
A/C duct layout |
|
|
|
Window schedule showing window sizes and
type, existing and proposed. Installation specifications, psf, and
anchoring method. |
|
Additional Information: Windows |
|
(provided in .pdf
format for downloading & printing.) |
|
|
|
Door schedule showing door sizes and
type, existing and proposed. Installation specifications, psf, and
anchoring method. |
|
|
|
Strength of concrete |
|
|
|
Attic access location (22" x
30" minimum) if required |
|
|
| ANY TWO STORY ADDITION on existing footers will require an engineer to verify that the existing
footer is adequate, or to make recommendations as to what will be required
to carry the additional load, signed and sealed. A tread and riser detail
and handrail/guardrail detail showing compliance with 2004 FBC Residential
Sections 311 and 312. |
| |
| ANY ALUMINUM CONSTRUCTION will require drawings by an engineer, with a raised seal, or an aluminum
contractor with engineering on file at the Building Department. |
| |
| ACCESSORY STRUCTURES - SWIMMING POOLS -
FENCES- DRIVEWAYS - SCREEN ROOMS - POOL
ENCLOSURES |
| |
|
DETACHED STRUCTURES -
(detached utility buildings, garages) - must have two (2) copies of
the property survey, to scale, showing the location of the proposed
construction, two (2) sets of construction drawings, to scale, showing
the size, type, and method of construction (frame/block), wall section
and location of overhead power lines. Construction over 200 sq. ft.
must be either sealed by an engineer or architect or show compliance
using the SSTD-1099 worksheets. Two (2) copies of components and
cladding (doors, windows, roofing, etc.) manufactures installation
requirements and Florida Product Approval information or signed and
sealed details by a profession engineer who is registered in the
State of Florida.
|
|
|
|
SWIMMING POOLS / SPAS -
(in ground and above ground) - must have two (2) copies (full size, to
scale) of the property survey from a least foundation stage, showing
the pool/spa location from all lot lines to the water’s edge and
distances from any other structure drawn to scale on the survey and
location of overhead power lines. Submit two (2) sets of plans showing
pool/spa size (length, depth, width), pool/spa specification and
equipment list, pump connections, pump horsepower, electrical
connections and GFI location, plumbing connections, and pool barrier detail. A set of signed and sealed engineered drawings must be on
file,
showing tank construction and indicating compliance with 2004 Florida Building Code, Chapter
424. |
|
|
|
FENCES / BLOCK WALLS -
must have two (2) copies of the property survey, to scale, showing the
proposed fence location, type (chain link, wood, block), total length
and height. |
|
|
|
DRIVEWAYS / CONCRETE SLABS -
must have two (2) copies of the property survey, to scale, and two (2)
sets of plans showing location and type of pavement, how deep, size
measurements and wire mesh or fiber mesh, and psi of concrete. A CITY USE PERMIT may be required if the
driveway goes to the City right-of-way. |
|
|
|
SCREEN ROOMS / POOL ENCLOSURES -
must have two (2) copies of the property survey, to scale, showing the
proposed size and location of the structure, and two (2) sets of
construction drawings showing method of construction. ALL construction is required to be done by a licensed
contractor and the drawings submitted must be signed and sealed
by an engineer or architect. |
|
|
|
MOBILE HOME SETUPS - must
have two (2) copies of a plot plan drawing showing the lot size, the
location and size of the mobile home being placed on the lot, and the
distance between this mobile home and abutting mobile homes. A letter
is required from the Mobile Home Park authorizing placement of the
mobile home. A Brevard County impact fee may be required. Indicate
tie-down method. |
|
|
REDUCED COPIES OF SURVEYS WILL NOT BE
ACCEPTED, ALL SURVEYS MUST BE A FULL COPY - TO SCALE |
|
|